Abstract:
Lately, electrically conductive concrete (ECC) is being investigated to prevent accumulation of snow and ice. The conductivity of electrical conductive concretes containing steel fiber is reduced by the corrosion of the steel fiber in time. Therefore, it is proposed to produce electrical conductive concretes that does not contain steel fibers recently. In this study, it is aimed to examine rebars in electrical conductive concretes non containing steel fiber. For this, 45 x 45 x 5 cm ECC slabs with and without Phi 10 rebars were produced. Carbon fiber was used as a single fiber type in the mixtures. The heating times and thermal behaviors of the slab specimens were examined in a cooler at about - 10 degrees C. According to the results, the temperature in the rebars reinforced specimens has increased first in the regions near the electrodes and then proceeds towards the middle of the specimen. In non-rebars specimens, temperature rise has started from random points.
Description:
Bu yayın 06.11.1981 tarihli ve 17506 sayılı Resmî Gazete’de yayımlanan 2547 sayılı Yükseköğretim Kanunu’nun 4/c, 12/c, 42/c ve 42/d maddelerine dayalı 12/12/2019 tarih, 543 sayılı ve 05 numaralı Üniversite Senato Kararı ile hazırlanan Sakarya Üniversitesi Açık Bilim ve Açık Akademik Arşiv Yönergesi gereğince açık akademik arşiv sistemine açık erişim olarak yüklenmiştir.