Abstract:
In the last decade many researchers have been carried out on semi-active control systems, a large number of academic publications have been presented. Semi-active control systems which are used the magnetic field controlled fluid have been shown significant improvements by the researchers. In the study, a design optimization method that has been carried out for the objectives of target damper force and maximum magnetic flux density of an MR damper has been presented. Finite element methods, electromagnetic analysis of magnetic field and CFD analysis of MR flow, have been used to obtain optimal value of design parameters. The new approach that is use of magnetic field and MR flow together and simultaneously has specified optimal design values. Two optimal design of MR damper obtained have been verified with experimental study by manufacturing and testing of the dampers. (C) 2012 Elsevier Ltd. All rights reserved.