Abstract:
In this study, the effect of welding current on the quality of weld joint and obviously on tensile-shear and tensile-peel strengths of galvanized chromate steel sheets having 1.2 mm thickness in electrical resistance spot welding was investigated. A timer and current controlled electrical resistance spot welding machine having 120 kVA capacity and pneumatic application mechanism with a single lever was used to prepare the specimens. Welding periods were chosen as 5, 10, 12 and 15 cycles and also welding currents were increased from 4 kA up to 12 kA by rise of 1 kA. The electrode force was kept constant at 6 kN. The prepared welding specimens were exposed to tensile-shear and tensile-peel tests and the obtained results were supported by diagrams and, finally, appropriate welding parameters were advised to the users. (c) 2005 Elsevier Ltd. All rights reserved.