Açık Akademik Arşiv Sistemi

Multi-DGAS: A pattern based educational framework design for power transformers faults interpretation and comparative performance analysis

Show simple item record

dc.contributor.authors Varan, M; Yurtsever, U;
dc.date.accessioned 2020-01-15T07:48:12Z
dc.date.available 2020-01-15T07:48:12Z
dc.date.issued 2018
dc.identifier.citation Varan, M; Yurtsever, U; (2018). Multi-DGAS: A pattern based educational framework design for power transformers faults interpretation and comparative performance analysis. COMPUTER APPLICATIONS IN ENGINEERING EDUCATION, 26, 227-215
dc.identifier.issn 1061-3773
dc.identifier.uri https://hdl.handle.net/20.500.12619/3983
dc.description.abstract Taking necessary measures in advance for early prediction of the transformer failures are very crucial. Dissolved gas in oil analysis (DGA) techniques that used in electrical power systems has become an internationally accepted standard in condition based maintenance (CBM) studies have high complexity and increasing demands of the quick-service-ready paradigm in power transformers. This standard includes the implementation steps of various complex DGA methods named basic gas, Rogers, Doernenburg, Duval triangle, and pentagon. Mentioned methods are quite complicated and their application steps are strict rules defined in detailed procedures. The adaptation of these methods to transformer maintenance procedures that prepared according to standards and tested for correctness creates a valuable tool. In this study, a pattern based educational framework has been designed to integrate state of arts DGA techniques help for trainers, graduate researchers working on DGA techniques, and also for maintenance teams while taking critical decisions on power transformers. Developed Multi-DGAS educational framework is designed for modular construction that can be integrated with online condition monitoring and diagnostic systems for electric power systems. Success of the proposed framework revealed with newly proposed pentagon method in regard with comparison of classical methods by using oil samples which have been taken under the energized condition of different 135 transformers within multi-phase which failure histories already known. Analysis of dissolved gases in transformer oil is performed according to ASTM-D 3612 procedure using 3800 GC Varian gas chromatograph apparatus.
dc.description.uri https://doi.org/10.1002/cae.21872
dc.language English
dc.publisher WILEY
dc.subject Engineering
dc.title Multi-DGAS: A pattern based educational framework design for power transformers faults interpretation and comparative performance analysis
dc.type Article
dc.identifier.volume 26
dc.identifier.startpage 215
dc.identifier.endpage 227
dc.contributor.department Sakarya Uygulamalı Bilimler Üniversitesi/Teknoloji Fakültesi/Elektrik Ve Elektronik Mühendisliği Bölümü
dc.contributor.saüauthor Varan, Metin
dc.contributor.saüauthor Yurtsever, Ulaş
dc.relation.journal COMPUTER APPLICATIONS IN ENGINEERING EDUCATION
dc.identifier.wos WOS:000427244700003
dc.identifier.doi 10.1002/cae.21872
dc.identifier.eissn 1099-0542
dc.contributor.author Varan, Metin
dc.contributor.author Yurtsever, Ulaş


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record