Abstract:
In this study, a steady-state thermal analysis was performed to evaluate the temperature gradients in the standard and two different partially stabilized ceramic coated pistons by using Abaqus (c) finite element (FE) software. A sharp increase in the temperature of the coated area of the piston was observed as a result of FE simulations. It is concluded that the annulus Y-PSZ coating may contribute better, as compared to Mg-PSZ, to decrease the cold start and steady state HC emissions without auto ignition, since the temperature in the area shows a local sharp increase. (C) 2011 Elsevier Ltd. All rights reserved.