Açık Akademik Arşiv Sistemi

Mass attenuation coefficients, effective atomic numbers and electron densities of some contrast agents for computed tomography

Show simple item record

dc.contributor.authors Al-Buriahi, MS; Tonguc, BT;
dc.date.accessioned 2020-01-20T08:02:44Z
dc.date.available 2020-01-20T08:02:44Z
dc.date.issued 2020
dc.identifier.citation Al-Buriahi, MS; Tonguc, BT; (2020). Mass attenuation coefficients, effective atomic numbers and electron densities of some contrast agents for computed tomography. RADIATION PHYSICS AND CHEMISTRY, 166, -
dc.identifier.issn 0969-806X
dc.identifier.uri https://hdl.handle.net/20.500.12619/32318
dc.identifier.uri https://doi.org/10.1016/j.radphyschem.2019.108507
dc.description.abstract In the clinical computed tomography (CT) examinations, a photon is attenuated as it passes a patient by tissues and contrast agents (CAs). The CM can increase the visibility of internal structures or fluids within the patient. In this work, we have investigated the photon interaction parameters of some CT contrast agents such as iotrolan, iodixanol, iohexol, ioxilan, ioversol, and iomeprol. The mass attenuation coefficients (mu/rho) of these contrast agents have been determined using Geant4 code in the energy range from 1 keV to 1 MeV for total photon interaction. The validity of the Geant4 code was verified by comparing the simulation results with those calculated by the XCOM program. A very good agreement was observed between mu/rho values obtained by both Geant4 and XCOM codes. The mu/rho values were then used to estimate the effective atomic numbers (Z(eff)) and electron densities (N-eff) for the selected CT contrast agents. It was found that the values of mu/rho, Z(eff) and N-eff depend on the photon energy and increase with increasing iodine concentration in the composition of CAs. Also, the Z(eff) values were observed in the range of 6-50 and the N-eff values were observed in the range of 2 - 21 (10(23) electron/g). The present study would be helpful to develop new CT contrast agents to serve in vivo imaging applications.
dc.language English
dc.publisher PERGAMON-ELSEVIER SCIENCE LTD
dc.subject Physics
dc.title Mass attenuation coefficients, effective atomic numbers and electron densities of some contrast agents for computed tomography
dc.type Article
dc.identifier.volume 166
dc.contributor.department Sakarya Üniversitesi/Fen-Edebiyat Fakültesi/Fizik Bölümü
dc.contributor.saüauthor Tonguç, Barış Tamer
dc.relation.journal RADIATION PHYSICS AND CHEMISTRY
dc.identifier.wos WOS:000501394400041
dc.identifier.doi 10.1016/j.radphyschem.2019.108507
dc.contributor.author Mohammed Sultan Al-Buriahi
dc.contributor.author Tonguç, Barış Tamer


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record