Açık Akademik Arşiv Sistemi

Performance Comparison of Thermal-Sprayed Coatings for Ductile Iron Pipe

Show simple item record

dc.contributor.authors Gulec, A; Cevher, O; Ustel, F; Turk, A; Akinci, A; Yilmaz, F
dc.date.accessioned 2020-10-16T11:39:30Z
dc.date.available 2020-10-16T11:39:30Z
dc.date.issued 2011
dc.identifier.citation Gulec, A; Cevher, O; Ustel, F; Turk, A; Akinci, A; Yilmaz, F (2011). Performance Comparison of Thermal-Sprayed Coatings for Ductile Iron Pipe. MATERIALS PERFORMANCE, 50, 36-30
dc.identifier.issn 0094-1492
dc.identifier.uri https://hdl.handle.net/20.500.12619/69966
dc.description.abstract In several countries, Zn and Zn/Al 85/15 coatings applied by thermal spray are used to protect underground ductile iron (DI) pipe against soil corrosion. In this study, DI pipe samples were coated with Zn and Zn/Al 85/15. Test results showed that Zn/Al 85/15 coatings have better corrosion resistance than Zn coatings and the annealing oxide on DI pipe acts as a good corrosion-resistant protective layer.
dc.language English
dc.publisher NATL ASSOC CORROSION ENG
dc.title Performance Comparison of Thermal-Sprayed Coatings for Ductile Iron Pipe
dc.type Article
dc.identifier.volume 50
dc.identifier.startpage 30
dc.identifier.endpage 36
dc.contributor.department Sakarya Üniversitesi/Mühendislik Fakültesi/Metalurji Ve Malzeme Mühendisliği Bölümü
dc.contributor.saüauthor Cevher, Özgür
dc.contributor.saüauthor Üstel, Fatih
dc.contributor.saüauthor Türk, Ahmet
dc.contributor.saüauthor Akıncı, Akın
dc.contributor.saüauthor Yılmaz, Fevzi
dc.relation.journal MATERIALS PERFORMANCE
dc.identifier.wos WOS:000295386200006
dc.contributor.author Cevher, Özgür
dc.contributor.author Üstel, Fatih
dc.contributor.author Türk, Ahmet
dc.contributor.author Akıncı, Akın
dc.contributor.author Yılmaz, Fevzi


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record