Açık Akademik Arşiv Sistemi

Failure Evaluation of Galvanized High Carbon Steel Spring Wires

Show simple item record

dc.contributor.authors Salik, YZ; Altuncu, E; Ustel, F;
dc.date.accessioned 2020-10-16T11:05:21Z
dc.date.available 2020-10-16T11:05:21Z
dc.date.issued 2019
dc.identifier.citation Salik, YZ; Altuncu, E; Ustel, F; (2019). Failure Evaluation of Galvanized High Carbon Steel Spring Wires. ACTA PHYSICA POLONICA A, 135, 649-646
dc.identifier.issn 0587-4246
dc.identifier.uri https://doi.org/10.12693/APhysPolA.135.646
dc.identifier.uri https://hdl.handle.net/20.500.12619/69669
dc.description.abstract High carbon steel wires are subjected to patented heat treatment after the surface cleaning process to obtain sufficient mechanical strength and toughness properties. As a result of this process, thin lamellar pearlitic microstructural features suitable for subsequent diameter reduction processes are obtained. Before entering the hot dip zinc bath, the surface is again subjected to pre-surface preparation. Afterwards, the wires reach the targeted coating thickness depending upon the dipping time in the molten zinc bath at 450 degrees C and a bright and smooth surface finish is obtained by cooling with air or water after stripping at the exit of the bath. Various discontinuities can be observed in the galvanized layer depending on the cooling rate and surface preparation process quality. The risk of failure to the galvanized wire due to these discontinuities during subsequent shaping or during diameter reduction is very high. In this study, a failure analysis was carried out on galvanized spring steel. The results showed that the failure is related to two main factors: the relatively poor surface quality and the unsuitable cooling rate of the wires after exiting from the galvanizing bath. In order to explain the origin of the failure, systematic metallographic investigations were performed by means of scanning electron microscope on both the wire surface and zinc layer cross-section. Mechanical behavior of wire was investigated on lifespan testing.
dc.language English
dc.publisher POLISH ACAD SCIENCES INST PHYSICS
dc.rights info:eu-repo/semantics/openAccess
dc.rights.uri http://creativecommons.org/licenses/by/4.0/
dc.subject Physics
dc.title Failure Evaluation of Galvanized High Carbon Steel Spring Wires
dc.type Proceedings Paper
dc.identifier.volume 135
dc.identifier.startpage 646
dc.identifier.endpage 649
dc.contributor.department Sakarya Uygulamalı Bilimler Üniversitesi/Teknoloji Fakültesi/Metalurji Ve Malzeme Mühendisliği Bölümü
dc.contributor.saüauthor Altuncu, Ekrem
dc.contributor.saüauthor Üstel, Fatih
dc.relation.journal ACTA PHYSICA POLONICA A
dc.identifier.wos WOS:000481717100023
dc.identifier.doi 10.12693/APhysPolA.135.646
dc.identifier.eissn 1898-794X
dc.contributor.author Y. Z. Salik
dc.contributor.author Altuncu, Ekrem
dc.contributor.author Üstel, Fatih


Files in this item

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess