Açık Akademik Arşiv Sistemi

Titanyum malzemelerin anodizasyon yöntemiyle titanyum oksit kaplanması ve karakterizasyonu.

Show simple item record

dc.contributor.advisor Profesör Doktor Cuma Bindal ; ortak danışman : Profesör Doktor Ahmet Hikmet Üçışık.
dc.date.accessioned 2021-03-02T10:47:21Z
dc.date.available 2021-03-02T10:47:21Z
dc.date.issued 2016
dc.identifier.citation Sarıca, Neslihan..(2016).Titanyum malzemelerin anodizasyon yöntemiyle titanyum oksit kaplanması ve karakterizasyonu.. Yayınlamlanmamış Doktora Tezi.Sakarya Üniversitesi Fen Bilimleri Enstitüsü, Sakarya
dc.identifier.uri https://hdl.handle.net/20.500.12619/76320
dc.description 06.03.2018 tarihli ve 30352 sayılı Resmi Gazetede yayımlanan “Yükseköğretim Kanunu İle Bazı Kanun Ve Kanun Hükmünde Kararnamelerde Değişiklik Yapılması Hakkında Kanun” ile 18.06.2018 tarihli “Lisansüstü Tezlerin Elektronik Ortamda Toplanması, Düzenlenmesi ve Erişime Açılmasına İlişkin Yönerge” gereğince tam metin erişime açılmıştır.
dc.description.abstract Titanyum yüzeyler, muhtemel tıp ve mühendislik uygulamalarında kullanılmak üzere nano tanecikli, nano pürüzlü ve nanotüplü yüzeyler olarak anodizasyon parametreleri değiştirilerek modifiye edilmiştir. Morfolojik yapıları incelemek için geleneksel mikroskobik yöntemler, taramalı elektron mikroskobu (SEM), enerji dağılımlı X ışını spektroskopisi (EDX) ve atomik kuvvet mikroskobu (AFM) kullanılmıştır. Oksit yüzeylerin mekanik özellikleri hakkında bilgi edinmek için nano-indentasyon ve nano tribolojik metotlar uygulanmıştır. Anodizasyon çözeltisinin kimyasal kompozisyonuna bağlı olarak ya pürüzlü yüzeyler, nano tanecikler ya da nanotüpler elde edilmiştir. Pürüzlü yüzeylerde, pürüzlülük anodizasyon voltajının ve süresinin artmasıyla birlikte artmaktadır. Pürüzlü yüzeyleri elde etmenin yanı sıra, kimyasal ve kristallografik farklılıklar bakımından homojen olmayan morfolojik yapılar da elde edilmiştir. Nanoindentasyon sonuçlarına gore nanopürüzlü yüzeylerin kaplama kalınlığı yaklaşık olarak 50-100 nm arasında değişmektedir. Bu testler, kaplama kalınlığının değiştiğini gösterdiği gibi sertlik değerlerinin de değiştiğini göstermektedir. Kaplanmış numuneler arasında nanotüp kaplı yüzey kırılgan yapısından dolayı en düşük sertliğe sahiptir. Numuneler üzerinde yapılan temas açısı ölçüm sonuçlarına göre, titanyum malzemeler kaplamadan sonra daha hidrofilik hale gelmiştir. Biyomalzeme kaynaklı enfeksiyona yol açan S. aureus bakteri çeşidi kaplanmış numunelerin antibakteriyel özelliklerini test etmek için numuneler üzerine ekilmiştir. Bakterileri, yüzeyde biyofilm oluşturmak üzere bir süre bıraktıktan sonra, yüzeydeki bakteriler SEM yardımıyla görüntülenmiştir. Nanotüp yüzeyler, porozlu ve /veya yüzey yapısından dolayı en çok bakteri tutan yüzey olarak gözlemlenmiştir. Bu çalışma sonucunda, anodizasyon parametrelerini, değiştirerek farklı yüzey morfolojisine ve kristallografisine sahip yüzeyler elde edilmiş ve bu değişiklere bağlı olarak bu yüzeylerin farklı mekanik ve antibakteriyel özelliklere sahip olduğu gözlemlenmiştir.
dc.description.abstract Titanium surfaces were modified in order to obtain nanosized grains, rough surfaces and nanotubes for the future applications in medicine and engineering by changing anodization parameters. Conventional microscopical techniques SEM (scanning electron microscopy), EDX (energy-dispersive X-ray spectroscopy) and AFM (atomic force microscopy) were applied to study morphological structures. Nanoindentations and nanotribological methods were applied to get informations on the effect of altered anodization parameters on mechanical behaviour of the oxide surfaces. Depending on chemical composition of the anodization solution either rough surfaces, nanograins or nanotubes were obtained. In case of the condition where rough surfaces were obtained roughness was increased with the increase in applied voltage and anodization time. In the same time other than obtaining rough surfaces inhomogeneous morphological structures in terms of chemistry and crystallographic differences were obtained. The thicknesses of the nanorough coatings were ranged roughly between 50-100 nm according to the nanoindentation tests. These tests also show that thickness of the coating varies and so does the hardness values. Among the samples, nanotube has the lowest hardness value due to its brittle nature. According to contact angle studies on the samples, it was found that titanium surfaces became more hydrophilic after anodization coating. The efficiency of the surfaces in preventing bacteria attachment were tested by seeding S. aureus on the titanium surface, which is the most common bacteria species causing biomaterial centered infections. After leaving the bacteria for a while to form biofilms, anti bacterial property of the surfaces were tested by visualizing the bacteria on the surfaces via SEM. Nanotube has the highest bacteria attachment on its surface, which may be resulted due to porosity and/or the feature of the surface of the nanotube. In this study, it was found that surfaces having different surface morphology and crystallography by altering the anodization parameters were obtained and these surfaces had different mechanical and antibacterial properties due to these changes.
dc.language Türkçe
dc.language.iso tur
dc.publisher Sakarya Üniversitesi
dc.rights.uri http://creativecommons.org/licenses/by/4.0/
dc.rights.uri info:eu-repo/semantics/openAccess
dc.subject Titanyum - oksijen-titanyum sistemi.
dc.subject Anodizasyon yöntemi.
dc.title Titanyum malzemelerin anodizasyon yöntemiyle titanyum oksit kaplanması ve karakterizasyonu.
dc.type doctoralThesis
dc.contributor.department Sakarya Üniversitesi, Fen Bilimleri Enstitüsü, Metalurji ve Malzeme Mühendisliği Anabilim Dalı,
dc.contributor.author Sarıca, Neslihan.
dc.relation.publicationcategory TEZ


Files in this item

This item appears in the following Collection(s)

Show simple item record

http://creativecommons.org/licenses/by/4.0/ Except where otherwise noted, this item's license is described as http://creativecommons.org/licenses/by/4.0/