Dereshgi, Hamid Asadi. (2019). Investigation of electro-mechanical factors effecting micro-pump characteristics for biomedical applications = Biyomedikal uygulamalarda kullanılan mikropompaların karakteristiğini etkileyen elektro-mekanik faktörlerin incelenmesi. (Yayınlanmamış Doktora Tezi). Sakarya Üniversitesi Fen Bilimleri Enstitüsü , Sakarya. |
|
dc.identifier.uri |
https://hdl.handle.net/20.500.12619/74297 |
|
dc.description |
06.03.2018 tarihli ve 30352 sayılı Resmi Gazetede yayımlanan “Yükseköğretim Kanunu İle Bazı Kanun Ve Kanun Hükmünde Kararnamelerde Değişiklik Yapılması Hakkında Kanun” ile 18.06.2018 tarihli “Lisansüstü Tezlerin Elektronik Ortamda Toplanması, Düzenlenmesi ve Erişime Açılmasına İlişkin Yönerge” gereğince tam metin erişime açılmıştır. |
|
dc.description.abstract |
Geçtiğimiz birkaç on yılda, mikro-elektro-mekanik sistemler (MEMS) teknolojilerindeki gelişmeler, çeşitli fonksiyonlarda mikroakışkan cihazların hızlı gelişimine katkıda bulunmuştur. MEMS'teki önemli elemanlardan biri, dakikada mililitre (ml) veya mikrolitre (µl) arasında değişen debiler üretebilen mikropompadır. Ticari bir mikropompa, basit yapıyı ve minyatürleştirmeyi, yüksek güvenilirliği, basit çalışma prensibini, düşük maliyeti ve karmaşık denetleyiciye gerek duymayan gerekçeler sunmalıdır. Bu çalışmada, pompalama hazneleri ve sabit rezervuarlar ile yüksek debi elde edebilen iki yeni piezoelektrik aktüatörlü (kurşun zirkonat titanat-PZT) valfsiz mikropompa tasarlanmış ve imal edilmiştir. Tek Diyaframlı Mikropompa (TDM) ve Çift-Diyaframlı Mikropompa (ÇDM) akış hızları üzerindeki hidrodinamik ve elektromekaniksel etkileri araştırmak için kapsamlı deneyler yapılmıştır. ÇDM, 180 derecelik faz kaymasıyla aynı hazneye bakan iki aktüatöre sahiptir. Önerilen tasarımların temel özellikleri, yenilikçi tasarım geometrisi ile düşük giriş gerilimlerinde ve frekanslarda yüksek debilerdir. Sabit hazneli entegre mikropompalar için tek adımlı üretim sağlayan 3D baskı tekniği kullanılmıştır. Mikropompa malzemeleri biyolojik olarak uyumludur ve maliyetleri azaltmak için tekrar tekrar kullanılabilir. Silikon diyaframın çekme testi, mikroskopi teknikleri ile yüzey topografya taraması ve hidrofobik özellik için damla şekli analizi gibi mekanik parametreler yüzey ıslanma ve akış stabilitesini ortaya çıkarmak için incelenmiştir. Ek olarak, rezervuar yüksekliğinin etkisi araştırılmış ve giriş voltajının uygulanmadığı dönemlerde kalibrasyon debileri ölçülmüştür. Maksimum diyafram deplasmanı 45 V ve 5 Hz'de elde edilmiştir. TDM ve ÇDM'nin maksimum akış hızı, 45 V ve 20 Hz'de sırasıyla 32.85 ml/dak ve 35.4 ml/dak'dır. Tüm giriş voltaj ve frekans seviyelerinde, ÇDM, TDM'den daha yüksek debiye sahiptir. |
|
dc.description.abstract |
In the past few decades, the advances in micro-electro-mechanical systems (MEMS) technologies have contributed to the rapid development of microfluidic devices in various functions. One of the important elements on MEMS is the micro-pump, which is capable of producing flow rates ranging in milliliter (ml) or microliter (μl) per minute. A commercial micro-pump should provide properties that justify the simple structure and miniaturization, high reliability, simple working principle, low cost and no need for complex controller. In this study, two novel piezoelectric actuated (lead zirconate titanate-PZT) valveless micro-pumps that can achieve high flow rates by pumping chambers and fixed reservoirs were designed and fabricated. Extensive experiments were conducted to investigate the effects of hydrodynamic and electromechanical on flow rates of the Single Diaphragm Micro-pump (SDM) and the Bi-diaphragm Micro-pump (BDM). BDM had two actuators facing to the same chamber at 180-degree phase shift. The primary features of the proposed designs were the high flow rates at low driving voltages and frequencies with the help of innovative design geometry. 3D-printing technique providing one-step fabrication for integrated micro-pumps with fixed reservoir was used. The micro-pump materials were biocompatible and can be used repeatedly to reduce costs. Mechanical parameters such as tensile test for silicon diaphragm, surface topography scanning by microscopy techniques and drop shape analysis for hydrophobic property were investigated to reveal surface wetting and flow stability. In addition, the effect of reservoir height was investigated and the calibration flow rates were measured during the inactive periods. The maximum diaphragm displacements were obtained at 45 V and 5 Hz. The maximum flow rate of SDM and BDM at 45 V and 20 Hz were 32.85 ml/min and 35.4 ml/min respectively. At all driving voltage and frequency levels, BDM had higher flow rates than of SDM. |
|
dc.format.extent |
X, 81 yaprak : şekil, tablo ; 30 cm. |
|
dc.language |
İngilizce |
|
dc.language.iso |
eng |
|
dc.publisher |
Sakarya Üniversitesi |
|
dc.rights |
info:eu-repo/semantics/openAccess |
|
dc.rights.uri |
http://creativecommons.org/licenses/by/4.0/ |
|
dc.subject |
Valfsiz mikropompa |
|
dc.subject |
Çift-diyafram |
|
dc.subject |
Piezoelektrik aktüatörler |
|
dc.subject |
Akışkan akışı ölçümü |
|
dc.subject |
Deplasman ölçümü |
|
dc.title |
Investigation of electro-mechanical factors effecting micro-pump characteristics for biomedical applications = Biyomedikal uygulamalarda kullanılan mikropompaların karakteristiğini etkileyen elektro-mekanik faktörlerin incelenmesi |
|
dc.type |
doctoralThesis |
|
dc.contributor.department |
Sakarya Üniversitesi, Mekatronik Mühendisliği Anabilim Dalı, Mekatronik Mühendisliği Bilim Dalı |
|
dc.contributor.author |
Dereshgi, Hamid Asadi |
|
dc.relation.publicationcategory |
TEZ |
|