dc.contributor.authors |
Aksoy, NO; Cakir, B; Dogan, E; Alagoz, G; |
|
dc.date.accessioned |
2020-01-17T11:59:29Z |
|
dc.date.available |
2020-01-17T11:59:29Z |
|
dc.date.issued |
2019 |
|
dc.identifier.citation |
Aksoy, NO; Cakir, B; Dogan, E; Alagoz, G; (2019). CORRELATIONS between Functional and Structural Tests Measured by Spectral Domain Optical Coherence Tomography in Severe Glaucoma. SEMINARS IN OPHTHALMOLOGY, , - |
|
dc.identifier.issn |
0882-0538 |
|
dc.identifier.uri |
https://hdl.handle.net/20.500.12619/7143 |
|
dc.identifier.uri |
https://doi.org/10.1080/08820538.2019.1648688 |
|
dc.description.abstract |
Purpose: To evaluate the relationship between visual acuity, visual field and spectral domain optical coherence tomography (OCT) parameters, including retinal nerve fiber layer (RNFL), ganglion cell-internal plexiform layer (GC-IPL) thicknesses, and optic nerve head parameters in patients with severe glaucoma. Material and Methods: Patients with the diagnosis of severe glaucoma were recruited from the data gathered at our glaucoma department. A detailed ophthalmic examination was performed using the Standard Automated Perimetry (the 30-2 SITA standard program was used for VF testing). Cirrus EDI-OCT was used for peripapillary RNFL and GC-IPL thickness measurements. Optic nerve head parameters, including mean cup-to-disc (c/d) ratio, rim area, vertical c/d ratio, cup volume, were also measured by spectral domain OCT. Correlations between these structural parameters and functional parameters (visual acuity, VF parameters) were investigated. Results: Forty-one eyes of 34 patients with severe glaucoma were enrolled in this study. Correlations between BCVA and mean GC-IPL thickness (p = .03), superior GC-IPL thickness (p = .03), inferonasal GC-IPL thickness (p = .01), superonasal GC-IPL thickness (p = .01), superotemporal GC-IPL thickness (p = .04), and rim area (p = .00) were found to be positive statistically significant. There was also a positive statistically significant correlation between MD and inferotemporal GC-IPL thickness (p = .03). Negative statistically significant correlations were found between BCVA and mean c/d ratio (p = .00), vertical c/d ratio (p = .02) and cup volume (p = .00). Discussion: Mean, superior, inferonasal, superonasal, and superotemporal GC-IPL thicknesses and mean c/d ratio, vertical c/d ratio and cup volume were found to be correlated with BCVA in patients with severe glaucoma. |
|
dc.language |
English |
|
dc.publisher |
TAYLOR & FRANCIS INC |
|
dc.subject |
Ophthalmology |
|
dc.title |
CORRELATIONS between Functional and Structural Tests Measured by Spectral Domain Optical Coherence Tomography in Severe Glaucoma |
|
dc.type |
Early Access |
|
dc.contributor.department |
Sakarya Üniversitesi/Tıp Fakültesi/Cerrahi Tıp Bilimleri Bölümü |
|
dc.contributor.saüauthor |
Özkan Aksoy, Nilgün |
|
dc.contributor.saüauthor |
Çakır, Burçin |
|
dc.relation.journal |
SEMINARS IN OPHTHALMOLOGY |
|
dc.identifier.wos |
WOS:000480198700001 |
|
dc.identifier.doi |
10.1080/08820538.2019.1648688 |
|
dc.identifier.eissn |
1744-5205 |
|
dc.contributor.author |
Özkan Aksoy, Nilgün |
|
dc.contributor.author |
Çakır, Burçin |
|
dc.contributor.author |
Emine Dogan |
|
dc.contributor.author |
Gursoy Alagoz |
|