Açık Akademik Arşiv Sistemi

CORRELATIONS between Functional and Structural Tests Measured by Spectral Domain Optical Coherence Tomography in Severe Glaucoma

Show simple item record

dc.contributor.authors Aksoy, NO; Cakir, B; Dogan, E; Alagoz, G;
dc.date.accessioned 2020-01-17T11:59:29Z
dc.date.available 2020-01-17T11:59:29Z
dc.date.issued 2019
dc.identifier.citation Aksoy, NO; Cakir, B; Dogan, E; Alagoz, G; (2019). CORRELATIONS between Functional and Structural Tests Measured by Spectral Domain Optical Coherence Tomography in Severe Glaucoma. SEMINARS IN OPHTHALMOLOGY, , -
dc.identifier.issn 0882-0538
dc.identifier.uri https://hdl.handle.net/20.500.12619/7143
dc.identifier.uri https://doi.org/10.1080/08820538.2019.1648688
dc.description.abstract Purpose: To evaluate the relationship between visual acuity, visual field and spectral domain optical coherence tomography (OCT) parameters, including retinal nerve fiber layer (RNFL), ganglion cell-internal plexiform layer (GC-IPL) thicknesses, and optic nerve head parameters in patients with severe glaucoma. Material and Methods: Patients with the diagnosis of severe glaucoma were recruited from the data gathered at our glaucoma department. A detailed ophthalmic examination was performed using the Standard Automated Perimetry (the 30-2 SITA standard program was used for VF testing). Cirrus EDI-OCT was used for peripapillary RNFL and GC-IPL thickness measurements. Optic nerve head parameters, including mean cup-to-disc (c/d) ratio, rim area, vertical c/d ratio, cup volume, were also measured by spectral domain OCT. Correlations between these structural parameters and functional parameters (visual acuity, VF parameters) were investigated. Results: Forty-one eyes of 34 patients with severe glaucoma were enrolled in this study. Correlations between BCVA and mean GC-IPL thickness (p = .03), superior GC-IPL thickness (p = .03), inferonasal GC-IPL thickness (p = .01), superonasal GC-IPL thickness (p = .01), superotemporal GC-IPL thickness (p = .04), and rim area (p = .00) were found to be positive statistically significant. There was also a positive statistically significant correlation between MD and inferotemporal GC-IPL thickness (p = .03). Negative statistically significant correlations were found between BCVA and mean c/d ratio (p = .00), vertical c/d ratio (p = .02) and cup volume (p = .00). Discussion: Mean, superior, inferonasal, superonasal, and superotemporal GC-IPL thicknesses and mean c/d ratio, vertical c/d ratio and cup volume were found to be correlated with BCVA in patients with severe glaucoma.
dc.language English
dc.publisher TAYLOR & FRANCIS INC
dc.subject Ophthalmology
dc.title CORRELATIONS between Functional and Structural Tests Measured by Spectral Domain Optical Coherence Tomography in Severe Glaucoma
dc.type Early Access
dc.contributor.department Sakarya Üniversitesi/Tıp Fakültesi/Cerrahi Tıp Bilimleri Bölümü
dc.contributor.saüauthor Özkan Aksoy, Nilgün
dc.contributor.saüauthor Çakır, Burçin
dc.relation.journal SEMINARS IN OPHTHALMOLOGY
dc.identifier.wos WOS:000480198700001
dc.identifier.doi 10.1080/08820538.2019.1648688
dc.identifier.eissn 1744-5205
dc.contributor.author Özkan Aksoy, Nilgün
dc.contributor.author Çakır, Burçin
dc.contributor.author Emine Dogan
dc.contributor.author Gursoy Alagoz


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record