Açık Akademik Arşiv Sistemi

Water recovery with combined membrane system in textile industry, treatment and management of concentrates by hybrid advanced oxidation/membrane filtration

Show simple item record

dc.contributor.authors Kiril Mert, B; Dogan, EC; Balci, E; Tilki, YM; Aksu, S; Goren, AY; Aydiner, C;
dc.date.accessioned 2020-02-26T08:57:11Z
dc.date.available 2020-02-26T08:57:11Z
dc.date.issued 2018
dc.identifier.citation Kiril Mert, B; Dogan, EC; Balci, E; Tilki, YM; Aksu, S; Goren, AY; Aydiner, C; (2018). Water recovery with combined membrane system in textile industry, treatment and management of concentrates by hybrid advanced oxidation/membrane filtration. PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 24, 475-468
dc.identifier.issn 1300-7009
dc.identifier.uri https://doi.org/10.5505/pajes.2017.984474
dc.identifier.uri https://hdl.handle.net/20.500.12619/50227
dc.description.abstract In this study, in addition to textile wastewater treatment by UF/NFtight/TO membrane combination of which efficiency is known, management has been performed for membrane concentrates generated with advanced oxidation combined process (Fenton and photo-Fenton (UVA-365-UVC-254))/submerged UF system of membrane concentrates generated within 75-80% water recovery ratio by oxidizing them in optimum operating conditions which were determined before. Ultimately in the studies, the conclusion has been reached that concentrate flows, generated as a result of the treatment with UF/NFtight/TO membrane configuration, were the highest performance innovative process by decreasing the sequential operated photo-Fenton (UVC-254)/UH050 hybrid process in ratios of 9.88 H2O2/TOK and 7.27 H2O2/Fe2+, in the filtration flux of 44 L/m(2). h, COD value to 167 mg/L with 86% COD removal, and TOK value to 104 mg/L with 74.2% TOC removal, after the oxidation with Fenton, photo-Fenton (UVA-365) and (UVC-254)/submerged UF system processes. When hazardous characteristics, removal/recovery methods and reuse alternatives of the concentrate remained after the oxidation of membrane concentrates generated were evaluated, it has been seen that all other concentrates of textile industry wastewater, except the concentrate generated by the treatment with photo-Fenton (UVA-365), had characteristics of hazardousness When removal/recovery methods were evaluated in detail, the conclusion has been reached that these concentrates could be removed with alternative options such as regular storage, burning and canalizing to central wastewater treatment system as long as necessary arrangements (moisture content, dehydration, suitable flow and/or mixture ratios) are made.
dc.language Turkish
dc.publisher PAMUKKALE UNIV
dc.rights info:eu-repo/semantics/openAccess
dc.rights.uri http://creativecommons.org/licenses/by/4.0/
dc.subject Engineering
dc.title Water recovery with combined membrane system in textile industry, treatment and management of concentrates by hybrid advanced oxidation/membrane filtration
dc.type Article
dc.identifier.volume 24
dc.identifier.startpage 468
dc.identifier.endpage 475
dc.contributor.department Sakarya Üniversitesi/Mühendislik Fakültesi/Çevre Mühendisliği Bölümü
dc.contributor.saüauthor Kırıl Mert, Berna
dc.relation.journal PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI
dc.identifier.wos WOS:000436191100016
dc.identifier.doi 10.5505/pajes.2017.984474
dc.identifier.eissn 2147-5881
dc.contributor.author Kırıl Mert, Berna
dc.contributor.author Esra C. Dogan
dc.contributor.author Esin Balci
dc.contributor.author Yasemin M. Tilki
dc.contributor.author Seyda Aksu
dc.contributor.author Aysegul Y. Goren
dc.contributor.author Coskun Aydiner


Files in this item

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess