On-line Preconcentration of Pd(II) Using Polyamine Silica Gel Filled Mini Column for Flame Atomic Absorption Spectrometric Determination

Show simple item record

dc.contributor.authors Sivrikaya, S; Karsli, B; Imamoglu, M;
dc.date.accessioned 2020-02-24T14:19:21Z
dc.date.available 2020-02-24T14:19:21Z
dc.date.issued 2017
dc.identifier.citation Sivrikaya, S; Karsli, B; Imamoglu, M; (2017). On-line Preconcentration of Pd(II) Using Polyamine Silica Gel Filled Mini Column for Flame Atomic Absorption Spectrometric Determination. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 11, 590-579
dc.identifier.issn 1735-6865
dc.identifier.uri https://doi.org/10.1007/s41742-017-0051-1
dc.identifier.uri https://hdl.handle.net/20.500.12619/45176
dc.description.abstract In this study, a novel method for determination of Pd(II) ions at trace level was developed using on-line preconcentration onto polyamine group bonded silica (PA-SG) with flame atomic absorption spectrometric determination. Pd(II) uptake dynamics of PA-SG was studied batchwise by investigating acidity and chloride concentration of aqueous phase, contact time and initial concentration of Pd(II) ions. The Pd(II) adsorption capacity of PA-SG was found to be 158.7 mg g(-1) from aqueous phase containing 0.1 M HCl. The on-line preconcentration procedure of Pd(II) was optimized with main analytical parameters including sample and eluent flow rate, eluent type and volume and matrix ions. The optimum eluent type and flow rate of sample and eluent were found to be 1.0% thiourea in 1.0 mol L-1 HCl and 7.5 mL min(-1), respectively. The preconcentration factor and sampling frequency were calculated to be 23.9 and 20 h(-1), respectively. The calibration graph was linear over the range 10-200 mu g L-1. The limits of detection (3 sigma) and quantification (10 sigma) values were computed to be 3 mu g L-1 and 10 mu g L-1, respectively. The RSD, % was found to be 4.6% for five measurement of 25 mu g L-1 of Pd(II) ions. The accuracy of the developed method was successfully checked by determination of Pd(II) level of certified reference material platinum ore (SARM 7B). The proposed method was successfully applied for Pd(II) determination in various environmental water samples such as river, lake, sea and tap water, and spent auto catalyst.
dc.language English
dc.publisher SPRINGER INTERNATIONAL PUBLISHING AG
dc.subject Environmental Sciences & Ecology
dc.title On-line Preconcentration of Pd(II) Using Polyamine Silica Gel Filled Mini Column for Flame Atomic Absorption Spectrometric Determination
dc.type Article
dc.identifier.volume 11
dc.identifier.startpage 579
dc.identifier.endpage 590
dc.contributor.department Sakarya Üniversitesi/Fen-Edebiyat Fakültesi/Kimya Bölümü
dc.contributor.saüauthor İmamoğlu, Mustafa
dc.relation.journal INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH
dc.identifier.wos WOS:000416266900003
dc.identifier.doi 10.1007/s41742-017-0051-1
dc.identifier.eissn 2008-2304
dc.contributor.author Sezen Sivrikaya
dc.contributor.author Bulent Karsli
dc.contributor.author İmamoğlu, Mustafa


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record