Açık Akademik Arşiv Sistemi

Electrochemical hydrogen peroxide sensor based on cobalt phthalocyanine captured in polyaniline film on a glassy carbon electrode

Show simple item record

dc.contributor.authors Ceken, B; Kandaz, M; Koca, A;
dc.date.accessioned 2020-02-24T14:15:08Z
dc.date.available 2020-02-24T14:15:08Z
dc.date.issued 2012
dc.identifier.citation Ceken, B; Kandaz, M; Koca, A; (2012). Electrochemical hydrogen peroxide sensor based on cobalt phthalocyanine captured in polyaniline film on a glassy carbon electrode. JOURNAL OF PORPHYRINS AND PHTHALOCYANINES, 16, 389-380
dc.identifier.issn 1088-4246
dc.identifier.uri https://doi.org/10.1142/S1088424612500447
dc.identifier.uri https://hdl.handle.net/20.500.12619/44847
dc.description.abstract This work demonstrated preparation, characterization, and application of a cobalt phthalocyanine based enzymeless/mediatorless hydrogen peroxide sensor. The cobalt phthalocyanine (CoPc) was retained in polyaniline (PANI) film on a glassy carbon electrode during electrochemical polymerization of aniline and consequently a novel composite electrode (GCE/PANI/CoPc) for the electrochemical sensor application was constructed. The CoPc functionalized composite electrode, GCE/PANI/CoPc, was evaluated by voltammetry, electrochemical impedance spectroscopy, and UV-vis spectroscopy. The results displayed retaining of the CoPc molecules in the PANI film on the GCE electrode. Presence of CoPc in PANI increased conductivity of the composite on the electrode. Sensing performance of the GCE/PANI/CoPc composite electrode to H2O2 were evaluated in detail with respect to the selectivity, reproducibility, repeatability, stability, linear concentration range, and sensitivity with voltammetric and double potential step chronoamperometric techniques. The GCE/PANI/CoPc composite electrode gives a linear range for H2O2 between 2 and 18 mu M H2O2 with sensitivities of 1.55 A.M-1 during the cathodic SWV scan and with sensitivities of 4.01 A.M-1 during the anodic SWV scan. A direct application of the sensor was performed in a real working condition, for the detection of hydrogen peroxide produced from the reaction between the glucose and glucose oxidase enzyme.
dc.language English
dc.publisher WORLD SCI PUBL CO INC
dc.subject Chemistry
dc.title Electrochemical hydrogen peroxide sensor based on cobalt phthalocyanine captured in polyaniline film on a glassy carbon electrode
dc.type Article
dc.identifier.volume 16
dc.identifier.startpage 380
dc.identifier.endpage 389
dc.contributor.department Sakarya Üniversitesi/Fen-Edebiyat Fakültesi/Kimya Bölümü
dc.contributor.saüauthor Kandaz, Mehmet
dc.relation.journal JOURNAL OF PORPHYRINS AND PHTHALOCYANINES
dc.identifier.wos WOS:000305158300006
dc.identifier.doi 10.1142/S1088424612500447
dc.identifier.eissn 1099-1409
dc.contributor.author Kandaz, Mehmet