Açık Akademik Arşiv Sistemi

The influence of column properties on metal speciation using high performance liquid chromatography-inductively coupled plasma mass spectrometry

Show simple item record

dc.contributor.authors Dundar, MS; Haswell, SJ;
dc.date.accessioned 2020-02-24T14:14:59Z
dc.date.available 2020-02-24T14:14:59Z
dc.date.issued 2001
dc.identifier.citation Dundar, MS; Haswell, SJ; (2001). The influence of column properties on metal speciation using high performance liquid chromatography-inductively coupled plasma mass spectrometry. ACTA CHIMICA SLOVENICA, 48, 227-215
dc.identifier.issn 1318-0207
dc.identifier.uri https://hdl.handle.net/20.500.12619/44828
dc.description.abstract This paper describes an investigation into the presence of artefacts associated with the column properties on metal speciation in chromatographic systems and identifies possible limitations of columns used. The analytical procedure developed consisted of a High Performance Liquid Chromatography coupled Inductively Coupled Plasma-Mass Spectrometry system. The separation characteristics of two reversed-phase high-performance liquid chromatography columns, Hamilton C-18-PRP-1 poly-(styrene divinylbenzene) co-polymer and a conventional silica based C-18-ODS, were assessed based on the separation of metal species present at trace levels as soluble low molecular weight organic acid species. A synthetic digestive system was also employed in this study based on an enzymolysis procedure to generate dietary available metal species in the presence of fibre and multivitamins. In general, the C-18-ODS column was found to give a better separation of the organic species present compared to the C-18-PRP-1 column due to the attraction of highly polar species to uncapped silanol groups in the C-18-ODS column. The study illustrated that samples may interact with the residual silanol groups and as a result produce artefacts of chromatographic retention mechanism, peak tailing and loss chromatographic resolution.
dc.language English
dc.publisher SLOVENSKO KEMIJSKO DRUSTVO
dc.subject Chemistry
dc.title The influence of column properties on metal speciation using high performance liquid chromatography-inductively coupled plasma mass spectrometry
dc.type Article
dc.identifier.volume 48
dc.identifier.startpage 215
dc.identifier.endpage 227
dc.contributor.department Sakarya Üniversitesi/Fen-Edebiyat Fakültesi/Kimya Bölümü
dc.contributor.saüauthor Dündar, Mustafa Şahin
dc.relation.journal ACTA CHIMICA SLOVENICA
dc.identifier.wos WOS:000169133300006
dc.identifier.eissn 1580-3155
dc.contributor.author Dündar, Mustafa Şahin


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)