dc.contributor.authors |
Tasdemir, Ismail; Kalabalik, Fahrettin; Aytugar, Emre |
|
dc.date.accessioned |
2022-12-20T13:24:58Z |
|
dc.date.available |
2022-12-20T13:24:58Z |
|
dc.date.issued |
2022 |
|
dc.identifier.issn |
1049-2275 |
|
dc.identifier.uri |
http://dx.doi.org/10.1097/SCS.0000000000008599 |
|
dc.identifier.uri |
https://hdl.handle.net/20.500.12619/99132 |
|
dc.description |
Bu yayının lisans anlaşması koşulları tam metin açık erişimine izin vermemektedir. |
|
dc.description.abstract |
Background: The aim of this study was to evaluate the prevalence of lingual cortical bone perforation caused by virtually placed implants on cone-beam computed tomography images in the edentulous mandibular canine region and determine the relationship between the morphological structure of the crest and the risk of perforation. Methods: Eight hundred dental implants were virtually inserted on 100 qualified cone-beam computed tomography scans. Crests were divided into 4 groups according to the crest morphology as Type U, Type L, Type P, and Type C. The distance between the implant tip and lingual plate was measured using a digital caliper. Incidence of lingual plate perforation and proximity of the implant tip to the lingual plate were measured for 4 types of the alveolar crest. Results: A total of 800 virtual implant applications were performed in 100 patients who met the inclusion criteria. The incidence of lingual plate perforation was found to be significantly higher in Type U crests than in the other types. It was also found to be statistically significantly higher in Type L crests than in Type P and Type C crests. When the relationship between implant length and perforation was evaluated, perforation in 14 mm implants was significantly higher than 8, 10, and 12 mm implants. Conclusions: According to the results of this study, it was determined that high rates of perforation occurred in the U and L type crests and 14 mm implants during implant surgery in the mandibular anterior edentulous region. |
|
dc.language |
English |
|
dc.language.iso |
eng |
|
dc.relation.isversionof |
10.1097/SCS.0000000000008599 |
|
dc.subject |
Surgery |
|
dc.subject |
Cone-beam computed tomography |
|
dc.subject |
dental implants |
|
dc.subject |
edentulous |
|
dc.subject |
mandible |
|
dc.subject |
perforation |
|
dc.title |
Risk Assessment of Lingual Plate Perforation in Anterior Edentulous Mandibular Region: A Virtual Implant Placement Study Using Cone-Beam Computed Tomography |
|
dc.contributor.authorID |
Aytugar, Emre/0000-0002-0686-6476 |
|
dc.identifier.volume |
33 |
|
dc.identifier.startpage |
2460 |
|
dc.identifier.endpage |
2462 |
|
dc.relation.journal |
JOURNAL OF CRANIOFACIAL SURGERY |
|
dc.identifier.issue |
8 |
|
dc.identifier.doi |
10.1097/SCS.0000000000008599 |
|
dc.identifier.eissn |
1536-3732 |
|
dc.contributor.author |
Tasdemir, Ismail |
|
dc.contributor.author |
Kalabalik, Fahrettin |
|
dc.contributor.author |
Aytugar, Emre |
|
dc.relation.publicationcategory |
Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı |
|