Açık Akademik Arşiv Sistemi

Determination of antibiotic susceptibility of bacteria by flow cytometric method

Show simple item record

dc.contributor.authors Hatipoglu, Huseyin; Erman, Gulay; Toptan, Hande; Koroglu, Mehmet; Altindis, Mustafa
dc.date.accessioned 2022-12-20T13:24:46Z
dc.date.available 2022-12-20T13:24:46Z
dc.date.issued 2022
dc.identifier.issn 0959-3993
dc.identifier.uri http://dx.doi.org/10.1007/s11274-022-03332-2
dc.identifier.uri https://hdl.handle.net/20.500.12619/98980
dc.description Bu yayının lisans anlaşması koşulları tam metin açık erişimine izin vermemektedir.
dc.description.abstract In this study, it was aimed to determine the antibiotic susceptibility of bacterial strains by using flow cytometry method by comparing them with current standardized methods. Eleven clinical isolates and 6 standard bacterial strains were included in the study. MIC values were determined by broth microdilution method (BMD), VITEK 2 (R) automated system and flow cytometric method (FCM). FCM was performed with the Accuri C6 flow cytometer. For all strains except P. aeuruginosa ATCC 27853 [BMD-FCM:r = 0.557(p = 0.048); VITEK 2-FCM:r = 0.529(p = 0.063)], E. faecalis ATCC 29212 [BMD-FCM:r = 0.393(p = 0.295); BMD-VITEK 2:r = 0.393(p = 0.295)], and vancomycin-resistant E. faecium clinical isolate [BMD-FCM:r = 0.452(p = 0.063)] r values were in the range of 0.802-0.969 for BMD-FCM (p < 0.001), 0.655-0.941 for BMD-VITEK 2 (p < 0.005) and 0.667-0.953 for FCM-VITEK 2 (p < 0.005). Correlation values of antibiotic susceptibility test results between three methods for Gram-negative bacteria were found as follows; r = 0.927(p < 0.001) for BMD-FCM, r = 0.851(p < 0.001) for BMD-VITEK 2, r = 0.807(p < 0.001) for VITEK 2-FCM. Correlation values were found as follows for Gram positive bacteria; r = 0.848(p < 0.001) for BMD-FCM, r = 0.877(p < 0.001) for BMD-VITEK 2, r = 0.800(p < 0.001) for VITEK 2-FCM. When all bacteria included in the study were evaluated as a total; it was r = 0.911(p < 0.001) for BMD-FCM, r = 0.888(p < 0.001) for BMD-VITEK 2, r = 0.835(p < 0.001) for VITEK 2-FCM. The methicillin resistance of the clinical methicillin resistant S. aureus isolate could not be detected by FCM. It was determined that there was a high level of correlation between methods. FCM shortens the duration of antibiotic susceptibility tests by 12-14 h and gives results within the same day. However, it has not been standardized to be widely used in microbiology laboratories and experienced personnel are needed for its implementation.
dc.language English
dc.language.iso eng
dc.relation.isversionof 10.1007/s11274-022-03332-2
dc.subject Biotechnology & Applied Microbiology
dc.subject Antibiotic
dc.subject Antibiotic resistance
dc.subject Antibiotic susceptibility
dc.subject Antibiotic susceptibility test methods
dc.subject Bacteria
dc.title Determination of antibiotic susceptibility of bacteria by flow cytometric method
dc.contributor.authorID Altindis, Mustafa/0000-0003-0411-9669
dc.contributor.authorID ERMAN, GULAY/0000-0002-9926-369X
dc.identifier.volume 38
dc.relation.journal WORLD JOURNAL OF MICROBIOLOGY & BIOTECHNOLOGY
dc.identifier.issue 9
dc.identifier.doi 10.1007/s11274-022-03332-2
dc.identifier.eissn 1573-0972
dc.contributor.author Hatipoglu, Huseyin
dc.contributor.author Erman, Gulay
dc.contributor.author Toptan, Hande
dc.contributor.author Koroglu, Mehmet
dc.contributor.author Altindis, Mustafa
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record