Açık Akademik Arşiv Sistemi

Mass attenuation coefficients, effective atomic numbers and electron densities of some contrast agents for computed tomography

Show simple item record

dc.date.accessioned 2021-06-08T09:11:19Z
dc.date.available 2021-06-08T09:11:19Z
dc.date.issued 2020
dc.identifier.issn 0969-806X
dc.identifier.uri https://hdl.handle.net/20.500.12619/95850
dc.description Bu yayının lisans anlaşması koşulları tam metin açık erişimine izin vermemektedir.
dc.description.abstract In the clinical computed tomography (CT) examinations, a photon is attenuated as it passes a patient by tissues and contrast agents (CAs). The CM can increase the visibility of internal structures or fluids within the patient. In this work, we have investigated the photon interaction parameters of some CT contrast agents such as iotrolan, iodixanol, iohexol, ioxilan, ioversol, and iomeprol. The mass attenuation coefficients (mu/rho) of these contrast agents have been determined using Geant4 code in the energy range from 1 keV to 1 MeV for total photon interaction. The validity of the Geant4 code was verified by comparing the simulation results with those calculated by the XCOM program. A very good agreement was observed between mu/rho values obtained by both Geant4 and XCOM codes. The mu/rho values were then used to estimate the effective atomic numbers (Z(eff)) and electron densities (N-eff) for the selected CT contrast agents. It was found that the values of mu/rho, Z(eff) and N-eff depend on the photon energy and increase with increasing iodine concentration in the composition of CAs. Also, the Z(eff) values were observed in the range of 6-50 and the N-eff values were observed in the range of 2 - 21 (10(23) electron/g). The present study would be helpful to develop new CT contrast agents to serve in vivo imaging applications.
dc.language English
dc.language.iso eng
dc.publisher PERGAMON-ELSEVIER SCIENCE LTD
dc.relation.isversionof 10.1016/j.radphyschem.2019.108507
dc.rights info:eu-repo/semantics/closedAccess
dc.subject DOSIMETRIC MATERIALS
dc.subject DOSE CALCULATIONS
dc.subject PHYSICS MODELS
dc.subject HUMAN TISSUES
dc.subject LIQUID WATER
dc.subject GEANT4
dc.subject PHOTON
dc.subject GLASSES
dc.subject WINXCOM
dc.subject XCOM
dc.title Mass attenuation coefficients, effective atomic numbers and electron densities of some contrast agents for computed tomography
dc.type Article
dc.contributor.authorID Tonguc, Baris Tamer/0000-0001-6334-2233
dc.identifier.volume 166
dc.relation.journal RADIATION PHYSICS AND CHEMISTRY
dc.identifier.doi 10.1016/j.radphyschem.2019.108507
dc.contributor.author Al-Buriahi, Mohammed Sultan
dc.contributor.author Tonguc, Baris T.
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record