dc.description Bu yayın 06.11.1981 tarihli ve 17506 sayılı Resmî Gazete’de yayımlanan 2547 sayılı Yükseköğretim Kanunu’nun 4/c, 12/c, 42/c ve 42/d maddelerine dayalı 12/12/2019 tarih, 543 sayılı ve 05 numaralı Üniversite Senato Kararı ile hazırlanan Sakarya Üniversitesi Açık Bilim ve Açık Akademik Arşiv Yönergesi gereğince açık akademik arşiv sistemine açık erişim olarak yüklenmiştir.
dc.description Bu yayın 06.11.1981 tarihli ve 17506 sayılı Resmî Gazete’de yayımlanan 2547 sayılı Yükseköğretim Kanunu’nun 4/c, 12/c, 42/c ve 42/d maddelerine dayalı 12/12/2019 tarih, 543 sayılı ve 05 numaralı Üniversite Senato Kararı ile hazırlanan Sakarya Üniversitesi Açık Bilim ve Açık Akademik Arşiv Yönergesi gereğince açık akademik arşiv sistemine açık erişim olarak yüklenmiştir.
dc.description.abstract Objectives: Many surgeons use uterine manipulator (UM) during laparoscopic hysterectomy (LH). In this study, we aimed to compare the outcomes of LH operations performed by using partially reusable UM with the articulated system (artUM) and disposable (dUM) UM without articulation. Materials and Methods: A total of 99 patients underwent the LH operation. This study was carried out with 35 of those 99 Caucasian patients who met the inclusion criteria. Group 1 consisted for 7 LH operations using the articulated RUMI (R) II/KOH-Efficient (TM) (Cooper Surgical, Trumbull, CT, USA) system (artUM), while Group II consisted of 28 patients using old-type V Care (R) (ConMed Endosurgery, Utica, New York, USA) dUM as UM. Results: Mean operation time was found to be 157.1 +/- 42.0 min. The operation time was found statistically longer in Group 1, consisted of artUM used patients (P = 0.006 and P < 0.05). No statistically significant difference was found between two groups in terms of surgical results such as, delta hemoglobin value (P = 0.483 and P < 0.05), length of hospital stay (P = 0.138 and P < 0.05), and postoperative maximum body temperature (P = 0.724 and P < 0.05). Conclusion: The UM type did not alter the surgical outcomes except the operating time in our study. According to our results, the surgical technique is a more significant variable than instruments used in LH for normal size uterus. Further prospective, large-scale studies comparing various UM systems are mandatory.
dc.language English
dc.language.iso eng
dc.publisher WOLTERS KLUWER MEDKNOW PUBLICATIONS
dc.relation.isversionof 10.4103/GMIT.GMIT_65_20
dc.rights info:eu-repo/semantics/openAccess
dc.subject Laparoscopic hysterectomy
dc.subject surgical outcomes
dc.subject uterine manipulator
dc.title Does Uterine Manipulator Type Affect Surgical Outcomes of Laparoscopic Hysterectomy?
dc.type Article
dc.identifier.volume 10
dc.identifier.startpage 19
dc.identifier.endpage 24
dc.relation.journal GYNECOLOGY AND MINIMALLY INVASIVE THERAPY-GMIT
dc.identifier.issue 1
dc.identifier.wos WOS:000613836100003
dc.identifier.doi 10.4103/GMIT.GMIT_65_20
dc.identifier.eissn 2213-3089
dc.contributor.author Yavuzcan, Ali
dc.contributor.author Altintas, Rasit
dc.contributor.author Yildiz, Gazi
dc.contributor.author Basbug, Alper
dc.contributor.author Bastan, Merve
dc.contributor.author Caglar, Mete
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.identifier.pmıd 33747768
dc.rights.openaccessdesignations DOAJ Gold


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record