Evaluation of the hygrothermal performance of external thermal insulation applications on the outer walls of existing buildings

Show simple item record

dc.date.accessioned 2021-06-03T11:02:16Z
dc.date.available 2021-06-03T11:02:16Z
dc.date.issued 2021
dc.identifier.issn 1300-1884
dc.identifier.uri https://www.doi.org/10.17341/gazimmfd.634585
dc.identifier.uri https://hdl.handle.net/20.500.12619/95425
dc.description Bu yayın 06.11.1981 tarihli ve 17506 sayılı Resmî Gazete’de yayımlanan 2547 sayılı Yükseköğretim Kanunu’nun 4/c, 12/c, 42/c ve 42/d maddelerine dayalı 12/12/2019 tarih, 543 sayılı ve 05 numaralı Üniversite Senato Kararı ile hazırlanan Sakarya Üniversitesi Açık Bilim ve Açık Akademik Arşiv Yönergesi gereğince açık akademik arşiv sistemine açık erişim olarak yüklenmiştir.
dc.description Bu yayın 06.11.1981 tarihli ve 17506 sayılı Resmî Gazete’de yayımlanan 2547 sayılı Yükseköğretim Kanunu’nun 4/c, 12/c, 42/c ve 42/d maddelerine dayalı 12/12/2019 tarih, 543 sayılı ve 05 numaralı Üniversite Senato Kararı ile hazırlanan Sakarya Üniversitesi Açık Bilim ve Açık Akademik Arşiv Yönergesi gereğince açık akademik arşiv sistemine açık erişim olarak yüklenmiştir.
dc.description.abstract One of the precautions taken in building industry in order to minimize the results of increasing energy consumption in the world is energy efficient design of the utilization process of the buildings. In order to ensure energy efficiency in buildings, heat loss through building envelope is tried to be minimized. In Turkey, recently, external thermal insulation applications have been proliferating with the effect of legal obligations and the needs of providing fuel preservation within residences. In this paper, it is researched how hygrothermal performance of the existing building walls would be affected by external thermal insulation applications. In the first chapter of this paper, external thermal insulation composite system (ETICS) applications observed in Istanbul Capa district are dealt with. In this region, it has seen that there are impermeable coatings on the existing wall surface of buildings where external thermal insulation is applied. In the second chapter, changes in water content, relative humidity rate and temperature of different wall types are calculated via simulation method. According to the results, when thermal insulation materials are applied on impermeable coatings on the walls, the moisture amount in the wall layers may reach critical levels in winter and this situation can cause deteriorations in the wall layers in the long term. For these reasons, it is important to handle external thermal insulation applications on existing buildings with a holistic approach and expertise.
dc.language Turkish
dc.language.iso Turkish
dc.publisher GAZI UNIV, FAC ENGINEERING ARCHITECTURE
dc.relation.isversionof 10.17341/gazimmfd.634585
dc.rights info:eu-repo/semantics/openAccess
dc.subject Thermal insulation
dc.subject ETICS
dc.subject hygrothermal performans
dc.subject WUFI 2D
dc.subject simulation
dc.title Evaluation of the hygrothermal performance of external thermal insulation applications on the outer walls of existing buildings
dc.type Article
dc.identifier.volume 36
dc.identifier.startpage 89
dc.identifier.endpage 103
dc.relation.journal JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY
dc.identifier.issue 1
dc.identifier.wos WOS:000595657400007
dc.identifier.doi 10.17341/gazimmfd.634585
dc.identifier.eissn 1304-4915
dc.contributor.author Kilicaslan, Aysegul Eksi
dc.contributor.author Kus, Hulya
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rights.openaccessdesignations Bronze


Files in this item

This item appears in the following Collection(s)

Show simple item record