Açık Akademik Arşiv Sistemi

Hemodynamic Monitoring Using A Pulse Counter Vigileo Flotrac Cardiac Output System In Transapical Off-Pump Minimally Invasive Mitral Valve Repair

Show simple item record

dc.date.accessioned 2021-01-22T12:21:05Z
dc.date.available 2021-01-22T12:21:05Z
dc.date.issued 2019
dc.identifier.citation KAPLAN H. S,KARADENİZ Ü,KAYA B,ERDEM A. F,KARA İ (2020). Hemodynamic Monitoring Using A Pulse Counter Vigileo Flotrac Cardiac Output System In Transapical Off-Pump Minimally Invasive Mitral Valve Repair. Eastern Journal of Medicine, 25(2), 177 - 183. Doi: 10.5505/ejm.2020.04557
dc.identifier.issn 1301-0883
dc.identifier.uri https://app.trdizin.gov.tr/makale/TXpZeE5qSTFOUT09/hemodynamic-monitoring-using-a-pulse-counter-vigileo-flotrac-cardiac-output-system-in-transapical-off-pump-minimally-invasive-mitral-valve-repair
dc.identifier.uri https://hdl.handle.net/20.500.12619/76142
dc.description.abstract The aim of this study was to present our anesthetic management and early hemodynamic recovery after transapical off-pump neochords implantation. Observational prospective study. The perioperative records of 13 patients who underwent mitral valve repair using the Neochord DS1000 system were analyzed. Hemodynamic measurements recorded with the Vigileo Flotrac invasive arterial cardiac output system were evaluated. Thirteen patients were included in the study. Transfusions of a total of 2 U of erythrocytes and 11 U of plasma were performed. After Neochord implantation, the mean cardiac output increased at a statistically significant level according to the values measured after induction p = 0.003. Increased cardiac output measurement after placement of the neochordaes and elimination of insufficiency have emerged as indications of early hemodynamic recovery
dc.language İngilizce
dc.language.iso eng
dc.relation.isversionof 10.5505/ejm.2020.04557
dc.rights info:eu-repo/semantics/openAccess
dc.rights.uri http://creativecommons.org/licenses/by/4.0/
dc.subject Mitral valve prolapse
dc.subject chorda tendinea
dc.subject cardiac output
dc.title Hemodynamic Monitoring Using A Pulse Counter Vigileo Flotrac Cardiac Output System In Transapical Off-Pump Minimally Invasive Mitral Valve Repair
dc.type article
dc.identifier.volume 25
dc.identifier.startpage 177
dc.identifier.endpage 183
dc.contributor.department Van Yüzüncü Yıl Üniversitesi, Anesteziyoloji ve Reanimasyon Bölümü, Van, Türkiye
dc.contributor.department Sakarya Üniversitesi, Anesteziyoloji ve Reanimasyon Anabilim Dalı
dc.contributor.department Sakarya Üniversitesi, Anesteziyoloji ve Reanimasyon Anabilim Dalı
dc.contributor.department Sakarya Üniversitesi, Anesteziyoloji ve Reanimasyon Anabilim Dalı
dc.contributor.department Sakarya Üniversitesi, Kalp Damar Cerrahisi Anabilim Dalı
dc.relation.journal Eastern Journal of Medicine
dc.identifier.issue 2
dc.identifier.doi 10.5505/ejm.2020.04557
dc.identifier.eissn 1339-3886
dc.contributor.author Havva SAYHAN KAPLAN
dc.contributor.author Ümit KARADENİZ
dc.contributor.author Burak KAYA
dc.contributor.author Ali Fuat ERDEM
dc.contributor.author İbrahim KARA
dc.relation.publicationcategory Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı


Files in this item

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess